SMART converters

Beside the basic transparent gateway mode for M-Bus message transmission, the converters provide a Smart mode with independent readout of M-Bus meters, displaying data in a web table and data exports in XML, XML (REST), and CSV formats. Meter search and address change. Sending SMTP emails and uploading exports to FTP. Diagnostic logging.

EthMBus-XL

SMART
M-Bus devices:
1-20
1-45
1-80
1-120
1-190
Power
12-30V
Protection
1500W
1500W
Temp.
from -40°C
to 60°C
Large amount of meters in a building, residential districts, parts of town and for industry (distances up to 1km).

EthMBus-5

SMART
M-Bus devices:
1-5
Power
9-27,5V
9-39,5V
Protection
1500W
1500W
Temp.
from -40°C
to 60°C
Meters in a building, near by buildings and for industry (distances 100s of meters).

EthMBus-5M

SMART
M-Bus devices:
1-5
Power
8,5-28V
8,5-40V
Protection
1500W
600W
Temp.
from 0°C
to 45°C
Meters within a building (distances 100s of meters).

EthMBus-3SL

SMART
M-Bus devices:
1-3
Power
8,26V
8,5-36V
Protection
400W
400W
Temp.
from 0°C
to 45°C
Local meters readout within rooms and adjacent rooms (dist. 10s of meters).

LITE converters

Basic converters operating only as a transparent gateway for M-Bus message transmission.

EthMBus-XL

LITE
M-Bus devices:
1-20
1-45
1-80
1-120
1-190
Power
12-30V
Protection
1500W
1500W
Temp.
from 0°C
to 60°C
Large amount of meters in a building, residential districts, parts of town and for industry (distances up to 1km).

EthMBus-5

LITE
M-Bus devices:
1-5
Power
9-27,5V
9-39,5V
Protection
1500W
1500W
Temp.
from 0°C
to 60°C
Meters in a building, near by buildings and for industry (distances 100s of meters).

EthMBus-5M

LITE
M-Bus devices:
1-5
Power
8,5-28V
8,5-40V
Protection
600W
1500W
Temp.
from 0°C
to 45°C
Meters within a building (distances 100s of meters).

EthMBus-3SL

LITE
M-Bus devices:
1-3
Power
8,26V
8,5-36V
Protection
400W
400W
Temp.
from 0°C
to 45°C
Local meters readout within rooms and adjacent rooms (dist. 10s of meters).

SECURE converters

The converters operate in transparent gateway mode for M-Bus message transmission with the option of encryption and authentication to ensure the confidentiality and integrity of data from M-Bus meters.

EthMBus-XL

SECURE
M-Bus devices:
1-20
1-45
1-80
1-120
1-190
Power
12-30V
Protection
1500W
1500W
Temp.
from -40°C
to 60°C
Large amount of meters in a building, residential districts, parts of town and for industry (distances up to 1km).

EthMBus-5

SECURE
M-Bus devices:
1-5
Power
9-27,5V
9-39,5V
Protection
1500W
1500W
Temp.
from -40°C
to 60°C
Meters in a building, near by buildings and for industry (distances 100s of meters).

EthMBus-5M

SECURE
M-Bus devices:
1-5
Power
8,5-28V
8,5-40V
Protection
600W
1500W
Temp.
from 0°C
to 45°C
Meters within a building (distances 100s of meters).

EthMBus-3SL

SECURE
M-Bus devices:
1-3
Power
8,26V
8,5-36V
Protection
400W
400W
Temp.
from 0°C
to 45°C
Local meters readout within rooms and adjacent rooms (dist. 10s of meters).

EthMBus-4M

M-Bus devices:
1-4
Power
8-28V
Protection
600W
600W
Temp.
from -20°C
to 50°C
Meters within a building (distances 100s of meters).
Legend:
Power
AC - recommended AC supply voltage range
DC - recommended DC supply voltage range
Protection
...W - TVS protection power of the M-Bus line
...W - TVS protection power of the power supply
Temp.
from ..°C to ..°C
recommended temperature range for converter use